TEM3 Moulded Case Circuit Breaker
TEM3 Moulded Case Circuit Breaker

Application
TEM3 series moulded case circuit breaker is suitable for industrial or commercial power and lighting with AC 50/60Hz, rated working voltage up to AC 600V/ DC250V,
rated current up to 1200A. It's a kind of economical breaker with the characters of stable and reliable function, beautiful appearance, small size and long life. It
can be used for conversion of line and infrequent starting motor. It can also be attached to install the accessories which have protection function for avoiding
loss-voltage. Under-voltage, The product can install connection line with front board and back board, it also can be equipped hand-operating apparatus of motor-
operating apparatus to control in a remote distance.
Main Technical Specications
Frame current 1nm(A) 400 600 800
Type 2P TEM3-402E TEM3-402E TEM3-602S TEM3-602S TEM3-802E TEM3-802S
3P TEM3-403E TEM3-403E TEM3-603S TEM3-603S TEM3-803E TEM3-803S
4P TEM3-404E TEM3-404E TEM3-604S TEM3-604S TEM3-804E TEM3-804S
Rated current In(A) 250, 300, 350, 400 500, 600 600, 710, 800,
Rated working voltage Ue(V) AC600, DC250 AC600, DC250 AC600, DC250
Rated insulation voltage Ui(V) 600 600 600
Rated impulse wishstand voltage Uimp(V) 6000 6000 6000
Ics(kA)O-t-CO AC220V/AC240V 35 50 50 85 50 100
AC380V 30 42 42 65 42 65
AC415V 25 35 35 50 35 50
AC440V/AC460V 25 35 35 50 35 50
AC480V/AC500V 18 25 25 35 25 45
AC600V 18 22 22 25 22 25
DC125V 20 30 30 50 30 50
DC250V 10 20 20 40 20 40
Ics(%Icu)O-t-CO-t-CO 100 100 100 100 100 50
Arc-over distance(mm) 100 100 100
Rated residual working Fixed
current In(A) Unfixed
Rated residualk working current In(A)
Breaking time at In(A)
Over-current tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic
Operational performance: electrical life (times) 1000 1000 500
Operational performance: mechanical life (times) 4000 2500 2500
Outline dimecsionsLWH 2P 257140113 280210113 280210113
3P 257140113 280210113 280210113
4P 257185113 280280113 280280113

Main Technical Specications

Frame current 1nm(A) 100 225
Type 2P TEM3-102E TEM3L-102E TEM3-102S TEM3L-102S TEM3-202E TEM3-202S
3P TEM3-103E TEM3L-103E TEM3-103S TEM3L-103S TEM3-203E TEM3-203S
4P TEM3-104E TEM3L-104E TEM3-104S TEM3L-104S TEM3-204E TEM3-204S
Rated current In(A) 10, 15, 20, 30, 40, 50, 60, 75,100 10, 15, 20, 30, 40, 50, 60, 75,100 10, 15, 20, 30, 40, 50, 60, 75,100 10, 15, 20, 30, 40, 50, 60, 75,100 10, 15, 20, 30, 40, 50, 60, 75,100 10, 15, 20, 30, 40, 50, 60, 75,100
Rated working voltage Ue(V) AC600, DC250 AC380-460(3P,4P) AC220/240(2P) AC600, DC250 AC380-460(3P,4P) AC220/240(2P) AC600, DC250 AC600, DC250
Rated insulation voltage Ui(V) 600 600 600 600 600 600
Rated impulse wishstand voltage Uimp(V) 6000 6000 6000 6000 6000 6000
Ics(kA)O-t-CO AC220V/AC240V 25 25 25 25 25 25
AC380V 14 14 14 14 14 14
AC415V 10 10 10 10 10 10
AC440V/AC460V 10 10 10 10 10 10
AC480V/AC500V 7.5 7.5 7.5
AC600V 5 5 5
DC125V 10 10 10
DC250V 5 5 5
Ics(%Icu)O-t-CO-t-CO 50 50 50 50 50 50
Arc-over distance(mm) 50 50 50 50 50 50
Rated residual working Fixed 0.03, 0.1, 0.3 0.03, 0.1, 0.3
current In(A) Unfixed 0.03, 0.1, 0.3 0.03, 0.1, 0.3
Rated residualk working current In(A) 0.5In 0.5In
Breaking time at In(A) 0.1sec 0.1sec
Over-current tripping device Hydraulicmagnetic Hydraulicmagnetic Thermalmagnetic Thermalmagnetic Thermalmagnetic Thermalmagnetic
Operational performance: electrical life (times) 1500 1500 1500 1500 1500 1500
Operational performance: mechanical life (times) 8500 8500 8500 8500 8500 8500

Outline dimecsions LWH

2P 1305060 1305060 1556060 1556060 16510560 16510560
3P 1307560 1307560 1559060 1559060 16510560 16510560
4P 1309060 1309060 15512060 15512060 16514060 16514060