TEM8X Moulded Case Circuit Breaker
TEM8X Moulded Case Circuit Breaker


Application
TEM8X Series moulded case circuit breaker is one of new type breakers which our company adopts international advanced design, manufacture technology to develop. The rated insulating voltage is 950V. Suitable for AC 50Hz (60Hz). Rated
working voltage 690V or below, rated working current is 12.5A to 630A of circuit and used in distributing electric energy. Non-frequent making and breaking in the normal conditions and protecting when circuit and installation are overload,
short circuit and lacking voltage. Rated shell-rack and the breaker whose current is under 400A, take protection effect when mouse cage motor's non-frequent start, breaking off working and protecting form overload, short circuit and lacking voltage. The product conforms to GB14048.2, IEC 60947-2 standards.

Main Technical Specications
Type Rated current of trip (In A) Pole number Rated insulating voltage (V) Rated operating distance (mm) Arcing-over distance (mm) Uitimate short circuit breakering capacity (kA) Short circuit breaking capacity (kA) Operation performance
ON OFF
TEM8X-100D 12.5,5,16,20
25,32,40,50
63,80,100
3P 4P 950 690 18 18 1500 8500
TEM8X-100N 25 25
TEM8X-100H 70 70
TEM8X-100L 150 150
TEM8X-160D 16,20,25,32,
40,50,63,80,
100,125,160
25 25 1000 7000
TEM8X-160N 35 35
TEM8X-160H 70 70
TEM8X-160L 150 150
TEM8X-250D 160,180,
200,225, 250
0 25 25 1000 7000
TEM8X-250N 36 36
TEM8X-250H 70 70
TEM8X-250L 150 150
TEM8X-400D 200,225,
250,300,
315,400
25 25 1000 4000
TEM8X-400N 36 36
TEM8X-400H 70 70
TEM8X-400L 150 150
TEM8X-630D 315,350,
400,500,
600,630
35 35 1000 4000
TEM8X-630N 45 45
TEM8X-630H 70 70
TEM8X-630L 150 150

Working Conditions
Rated current of release(A) Thermodynamic release(ambient temp+40) Operational current of magnetic release(A)
1.05In(cold state)inoperation time(h) 1.30In(heat state) operative time(h)
In63 1 < 1 10In20%
63In100 2 < 2 10In20%
100In630 2 < 2 5-10In20%


Rated current of release(A) Thermodynamic release(ambient temp+40) Operational current of magnetic release(A)
1.0In(cold state) operative time(h) 1.20In(heat state) operative time(h) 1.50In(heat state) operative time(h) 1.01In (heat state) operative time(h)
12.5In400 2 < 2 4min 2S<Tp10S 12In20%

Outline and lnstallation Dimensions

MM C C1 C2 C3 C6 C7 C20 C21 G G1 G4
TEM8X-100/160/250D/N/H/L 29 76 54 108 43 104 34 86 62.5 125 70
TEM8X-400/630D/N/H/L 41.5 116 92.5 184 53 146 46.5 126 100 200 113.5

MM K2 L L1 L2 P1 P2 P4 P5 P6 R R1
TEM8X-100/160/250D/N/H/L 70 52.5 105 140 81 86 111 83 88 14.5 29
TEM8X-400/630D/N/H/L 90 70 140 185 95.5 110 168 107 112 31.5 63

MM K2 L L1 L2 P1 P2 P4 P5 P6 R R1
TEM8X-100/160/250D/N/H/L 70 52.5 105 140 81 86 111 83 88 14.5 29
TEM8X-400/630D/N/H/L 90 70 140 185 95.5 110 168 107 112 31.5 63

MM R2 R4 R5 R6 R7 R12 R13 T T4 (Ue)
TEM8X-100/160/250D/N/H/L 54 108 143 29 58 43 86 6 22 32
TEM8X-400/630D/N/H/L 71.5 143 188 46.5 93 63 126 6 32 32